5g Base Station Communication Power Supply Aging Test Equipment
Project | Specification requirements |
Reference size (D*W*H) | D1000mm*W600mm*H1700mm |
Burn-in test capacity | 1200W/CH,60CH |
Rated working voltage | AC:380VAC/Three-phase+10%/-15% |
Rated insulation voltage | 690VAC |
Rated frequency | 50Hz |
Rated working current | Input:360A |
Operating temperature | 5℃-45℃ |
Output channel specifications | 380VAC/Three-phase 60A |
Protective function | Support smoke sense, over temperature, and three-color light display status at the same time
|
Monitoring rate | The refresh interval of digitally collected information in the cabinet needs to be less than 1S
|
Smoke sensor type | Overhead installation type smoke sense, normally closed point work |
Flammability rating | All materials of the cabinet must meet the 99-V0 rating |
Temperature rise of power distribution components | Complies with the provisions of IEC 60947-1 on temperature rise, and the temperature rise value does not exceed the corresponding standard requirements of the component
|
Leakage Protection | The power input of the cabinet must match the power leakage protection function of the equipment. The AC side needs to be installed with a 30mA leakage protection circuit
|
Monitoring / instruction requirementsc | Equipped with 19-inch LCD display, keyboard and mouse and other interactive components,using a computer to monitor the lower computer
|
The man-machine interface is used to display the PLC collection temperature, control status, system status, fan running status, DD & DA equipment status, cabinet input AC power and other information in the cabinet. DD & DA status query and setting are monitored by the test monitoring board
|