Industrial High Power Charger Adapter Burn-In Testing Facility
common enquiries | Capacity | Maximum feedback power of burn-in products | 54KW@1000A |
Full load feedback efficiency | >85% | ||
Maximum power consumption at full load | <15KW | ||
Number of channels | A total of 6 floors, each with 12 channels of 1500W | ||
Number of loads | A total of 6 layers, 12 loads per layer, a total of 72 loads CP8503 | ||
Single channel minimum load current | ≤0.5A | ||
Available space on each floor of internal wall | Length ≥1.8m, depth ≥0.5m | ||
Equipment use environment | Temperature -10 ~ 55 ℃, humidity 0 ~ 95% | ||
Input requirements | Input voltage | Each layer is DC-48 power supply (-48V voltage range 38.5 ~ 72V, and there are repeated on and off input, it is recommended that the energy be fed back to AC three-phase power)
| |
Switch control | Each layer is equipped with a contactor (1 contactor can not meet the flow, one contactor every 3 stations), the single-layer module is controlled by the remote through the contactor to power on and off, the contactor repeats 200ms cycle under the maximum power flow It can't be invalid after 10000 disconnection
| ||
Input cable | When running at full power, the cable flow requirement cannot be exceeded, and the cableselection needs to meet the high temperature requirements of 105 ℃ and above
| ||
Input terminal | The input side copper wire is routed, the copper wire guarantees the current flow at full load,the maximum input current of a single tested module is 50A
| ||
Auxiliary source | Each layer provides 12 auxiliary source interfaces with an output voltage of 12V and a current of 2A or more. The auxiliary sources are isolated from each other to supply power to the monitoring board and Huawei fans.The auxiliary source will not be powered down by the input contactor of each layer
| ||
Output requirements | Output voltage | 3~60Vdc | |
load mode | CC | ||
Output cuurent | 1500W @ 120A, the current setting accuracy is ± 3%, the minimum load current is 0.5A, each channel can independently control the load current, and the load CC mode is set to a
| ||
Output voltage report | Error is less than +/- 0.2V | ||
Output socket | Each test slot needs to be equipped with a pair of terminals, each station is equipped with 8 output terminals (positive and negative), the terminal flow ≥20A
| ||
Temperature | The internal working temperature range of the burn-in cabinet is room temperature ~ 70 degrees, and the time for heating up to 70 degrees is not more than 30min. Each temperature within the working temperature range can work for a long time. There is a tem perature control zone on every two floors, the temperature of each control zone is controlled separately, and the temperature deviation is +/- 3 degrees
|