Add to Cart
Vehicle Electric Drive Controller Micro Control Unit Typical Burn-In Test Rack
Architecture diagram
System | System structure | 1 control cabinet + 2 aging cabinets + 1 water temperature cabinet |
Overall size | 6900*1600*2050mm | |
Total floor area | 6900*2500mm(Including operation area) | |
Total input voltage | Three-phase five-wire system 220Vac (rated) | |
Total input current | 250A | |
Total input power | 150kW | |
Application ambient temperature | 0-40℃ | |
Application environment humidity | 0-95% | |
Fire protection requirements | Materials meet UL 94V0 rating | |
Environmental requirements | Materials comply with Rohs, WEEE requirements | |
Safety requirements | Comply with IEC62368 international standard design requirements | |
Burn-in cabinet | Burn-in bits/cabinet | 16 bits/cabinet |
Burn-in bits/layer | 4 bits/layer | |
Burn-in product power | 20kW/bit | |
Burn-in product input voltage | 150-1000Vdc | |
Burn-in product input current | 50A/bit | |
Burn-in Product Load Category | Inductive/Motor/AC Feedback Load | |
Burn-in product load current | 350A (inductor/motor)/40A (AC feedback load) | |
Auxiliary voltage of Burn-in products | 8-30Vdc | |
Auxiliary current of Burn-in products | 10A | |
Power Connector Type | SB50 (HV+/HV-) | |
Load Connector Type | SB350 (U/V/W/PE) | |
Signal Connector Type | 24Pin 5566 | |
Input power | 320kW | |
Feedback power | 256kW |