Add to Cart
Burn-In Test Equipment Of Automotive Control Chip Microcontroller Unit Module
System | System structure | 1 control cabinet + 2 aging cabinets + 1 water temperature cabinet |
Overall size | 6900*1600*2050mm | |
Total floor area | 6900*2500mm(Including operation area) | |
Total input voltage | Three-phase five-wire system 220Vac (rated) | |
Total input current | 250A | |
Total input power | 150kW | |
Application ambient temperature | 0-40℃ | |
Application environment humidity | 0-95% | |
Safety requirements | Comply with IEC62368 international standard design requirements | |
Burn-in cabinet | Burn-in bits/cabinet | 16 bits/cabinet |
Burn-in bits/layer | 4 bits/layer | |
Burn-in product power | 20kW/bit | |
Burn-in product input voltage | 150-1000Vdc | |
Burn-in product input current | 50A/bit | |
Burn-in Product Load Category | Inductive/Motor/AC Feedback Load | |
Burn-in product load current | 350A (inductor/motor)/40A (AC feedback load) | |
Power Connector Type | SB50 (HV+/HV-) | |
Load Connector Type | SB350 (U/V/W/PE) | |
Signal Connector Type | 24Pin 5566 | |
Input power | 320kW | |
Feedback power | 256kW | |
Constant temperature range | Room temperature+5°C-60°C | |
Constant temperature accuracy | ±5°C | |
Number of temperature control points | 5 | |
Open type | Sliding door/folding door/side door | |
Volume size | 2100*1600*2050mm | |
Dimensions in the product area | 1700*550*1500mm | |
Product area layers | 4 | |
Top floor height | 1450mm | |
Product area air duct direction | Left and right ventilation | |
Cooling method | Air cooling | |
Material | 1.5mm cold rolled sheet | |
Water temperature cabinet | Water temperature range | Room temperature+5°C-60°C |
Water temperature accuracy | ±5°C | |
Water temperature | 8 | |
Number of serial products/way | 4/way | |
Dissipated power/circuit | 4kW/way | |
Channel diameter | 3/4 inch | |
Volume size | 880*1000*1900mm | |
Monitoring software | Display running information |
Input voltage, current, power, output voltage
|
Show status information |
Not Connected / Vacant / Passed / Under Voltage / Under Current / Over Voltage / Over Current / No Output / Protection
| |
Display accuracy | ±(1%+0.2%FS) | |
Control precision | ±(1%+0.2%FS) | |
Bad way of reporting | Audible alarm | |
Scan speed | 5S | |
Control cabinet | Control system | Window 10 |
Display medium | Computers and Monitors | |
Manipulating medium | Mouse and keyboard | |
Communication method | Cable | |
Type of protection |
Over current, leakage, over temperature, smoke, emergency stop
| |
Alarm method | Sound and light alarm, remote network | |
Heat dissipation type | Air cooling | |
Maintenance mode | Post maintenance | |
Material | 1.5mm cold rolled sheet | |
Volume size | 880*860*1900mm |