New Energy Pure Electric Vehicle BMS Module Aging Test Experimental Cabinet

Ask Latest Price
Video Channel
Brand Name :CPET
Model Number :CP-BMS03
Place of Origin :China
MOQ :2sets
Price :8800dollars/set
Payment Terms :L/C
Supply Ability :30sets/month
Delivery Time :45 work days
Packaging Details :Wooden case packing
Warranty period :12 months
Aging quantity :36
Rated working current :32A
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

New Energy Pure Electric Vehicle BMS Module Aging Test Experimental Cabinet

Performance parameters
New Energy Pure Electric Vehicle BMS Module Aging Test Experimental Cabinet
Skills requirement Burn-in cabinet size(mm) L1600*W1100*H1600
Rated working voltage 380Vac
Rated insulation voltage 690Vac
Rated frequency 50Hz
Rated working current 32A
Power frequency withstand
voltage for 1 minute
2500Vac
UUT input specifications 12VDC/5Amax*36passageway
UUT output specifications Static burn-in without load
Number of burn-in stations 36 (6 layers * 6, hierarchical control)
Burn-in temperature requirements

Product area (50 ℃ ~ 85 ℃) can be set, ± 3 ℃ precise control

Temperature rise

Requires a temperature rise from room temperature to 85 ° C within 15 minutes. When the internal temperature is high,the surface temperature of the burn-in cabinet is below 35 °

Branch switch 6 way 10A/30mA/3P or 1P
Structural requirements Dimension(mm) 1600(W)*1100(D)*1600(H)
In and out line Support next in and next out
Installation method Floor installation
Burn-in slot layout requirements

6 layers, 6 burn-in (3 before 3) slots per layer; each layer is individually powered on

Monitor and indicate Monitoring requirements

Touch screen displays the power-on state and sensor state of each slot

Safety requirements

1.With power supply, product and other key components short-circuit, over-current field energy analysis


2.With energy analysis under over-temperature, smoke and liquid leakage scenarios


3.The control circuit has a leakage protection function


4.Possess the ability to detect and operate ground faults and leakage faults


5.PLC control, real-time monitoring of burn-in cabinet status

Panel instructionsv Status indicator of each slot